Alarms#

class SpaceCenter.AlarmManager#

Alarm manager. Obtained by calling SpaceCenter.alarm_manager.

alarms: List#

A list of all alarms.

Attribute:

Read-only, cannot be set

alarms_with_type(type: SpaceCenter.AlarmType): List#

A list of all alarms of the given type.

Parameters:

type – The type of alarm to return.

alarm_with_name(name: string): SpaceCenter.Alarm | nil#

Returns the first alarm with the given title, or nil if no such alarm exists. Alarm titles are not guaranteed to be unique; if more than one alarm shares the given title, the first one found is returned.

Parameters:

name – The title of the alarm to return.

staticmethod add_alarm(time: number, title?: string, description?: string): SpaceCenter.Alarm#

Create an alarm.

Parameters:
  • time – Number of seconds from now that the alarm should trigger.

  • title – Title for the alarm. Defaults to 'Alarm'.

  • description – Description for the alarm. Defaults to ''.

staticmethod add_vessel_alarm(
    time: number,
    vessel: SpaceCenter.Vessel,
    title?: string,
    description?: string
): SpaceCenter.Alarm#

Create an alarm linked to a vessel.

Parameters:
  • time – Number of seconds from now that the alarm should trigger.

  • vessel – Vessel to link the alarm to.

  • title – Title for the alarm. Defaults to 'Vessel Alarm'.

  • description – Description for the alarm. Defaults to ''.

staticmethod add_apoapsis_alarm(
    vessel: SpaceCenter.Vessel,
    offset?: number,
    title?: string,
    description?: string
): SpaceCenter.Alarm#

Create an alarm for the given vessel’s next apoapsis.

Parameters:
  • vessel – The vessel.

  • offset – Time in seconds to offset the alarm by. Defaults to 60.0.

  • title – Title for the alarm. Defaults to 'Apoapsis Alarm'.

  • description – Description for the alarm. Defaults to ''.

staticmethod add_periapsis_alarm(
    vessel: SpaceCenter.Vessel,
    offset?: number,
    title?: string,
    description?: string
): SpaceCenter.Alarm#

Create an alarm for the given vessel’s next periapsis.

Parameters:
  • vessel – The vessel.

  • offset – Time in seconds to offset the alarm by. Defaults to 60.0.

  • title – Title for the alarm. Defaults to 'Periapsis Alarm'.

  • description – Description for the alarm. Defaults to ''.

staticmethod add_maneuver_node_alarm(
    vessel: SpaceCenter.Vessel,
    node: SpaceCenter.Node,
    offset?: number,
    add_burn_time?: boolean,
    title?: string,
    description?: string
): SpaceCenter.Alarm#

Create an alarm for the given vessel and maneuver node.

Parameters:
  • vessel – The vessel.

  • node – The maneuver node.

  • offset – Time in seconds to offset the alarm by. Defaults to 60.0.

  • add_burn_time – Whether the node’s burn time should be included in the alarm. Defaults to true.

  • title – Title for the alarm. Defaults to 'Maneuver Node Alarm'.

  • description – Description for the alarm. Defaults to ''.

staticmethod add_soi_alarm(
    vessel: SpaceCenter.Vessel,
    offset?: number,
    title?: string,
    description?: string
): SpaceCenter.Alarm#

Create an alarm for the given vessel’s next sphere of influence change.

Parameters:
  • vessel – The vessel.

  • offset – Time in seconds to offset the alarm by. Defaults to 60.0.

  • title – Title for the alarm. Defaults to 'SOI Change Alarm'.

  • description – Description for the alarm. Defaults to ''.

staticmethod add_transfer_window_alarm(
    vessel: SpaceCenter.Vessel,
    target: SpaceCenter.CelestialBody,
    title?: string,
    description?: string
): SpaceCenter.Alarm#

Create an alarm for the next planetary transfer window from the vessel’s current parent body to the target body.

Parameters:
  • vessel – The vessel.

  • target – The target body.

  • title – Title for the alarm. Defaults to 'Transfer Window Alarm'.

  • description – Description for the alarm. Defaults to ''.

Note

This relies on KSP’s stock transfer-window alarm logic. If KSP cannot compute a transfer from the vessel’s current parent body to the target, the resulting alarm may not fire at a useful time; in that case the properties on the returned alarm can still be used to inspect or adjust it.

class SpaceCenter.Alarm#

An alarm. Can be accessed using SpaceCenter.alarm_manager.

id: number#

Unique identifier of the alarm. KSP destroys and recreates an alarm when it is edited. This id will remain constant between the old and new alarms.

Attribute:

Read-only, cannot be set

type: SpaceCenter.AlarmType#

Type of alarm.

Attribute:

Read-only, cannot be set

title: string#

Title of the alarm.

Attribute:

Can be read or written

description: string#

Description of the alarm.

Attribute:

Can be read or written

time: number#

Time the alarm will trigger, in seconds since epoch.

Attribute:

Can be read or written

time_until: number#

Time until the alarm triggers, in seconds.

Attribute:

Read-only, cannot be set

event_offset: number#

Seconds between the alarm going off and the event it references.

Attribute:

Can be read or written

Note

For a maneuver alarm that includes the burn time, setting this sets the margin before the start of the burn, and the value read back includes half the burn time.

vessel: SpaceCenter.Vessel | nil#

Vessel the alarm references. nil if it does not reference a vessel.

Attribute:

Read-only, cannot be set

node: SpaceCenter.Node#

Maneuver node the alarm references. Only valid for alarms of type SpaceCenter.AlarmType.maneuver.

Attribute:

Can be read or written

Note

Throws an exception if the alarm is not of type SpaceCenter.AlarmType.maneuver.

origin_body: SpaceCenter.CelestialBody#

Origin body for the transfer window. Only valid for alarms of type SpaceCenter.AlarmType.transfer_window.

Attribute:

Can be read or written

Note

Throws an exception if the alarm is not of type SpaceCenter.AlarmType.transfer_window.

destination_body: SpaceCenter.CelestialBody#

Destination body for the transfer window. Only valid for alarms of type SpaceCenter.AlarmType.transfer_window.

Attribute:

Can be read or written

Note

Throws an exception if the alarm is not of type SpaceCenter.AlarmType.transfer_window.

warp_action: SpaceCenter.AlarmWarpAction#

The action taken on time warp when the alarm fires.

Attribute:

Can be read or written

message_action: SpaceCenter.AlarmMessageAction#

The on-screen message behavior when the alarm fires.

Attribute:

Can be read or written

play_sound: boolean#

Whether the alarm plays a sound when it fires.

Attribute:

Can be read or written

delete_on_dismiss: boolean#

Whether the alarm is deleted automatically once the player has dismissed the triggered message.

Attribute:

Can be read or written

triggered: boolean#

Whether the time of the alarm has passed and its actions have been triggered.

Attribute:

Read-only, cannot be set

actioned: boolean#

Whether the alarm’s actions were triggered and then completed or closed.

Attribute:

Read-only, cannot be set

remove()#

Removes the alarm.

Note

Any further use of this object throws an exception.

class SpaceCenter.AlarmType#

The type of an alarm. See SpaceCenter.Alarm.type.

raw#

An alarm for a specific date/time or a specific period in the future.

apoapsis#

An alarm for the next apoapsis of a vessel.

periapsis#

An alarm for the next periapsis of a vessel.

maneuver#

An alarm based on a maneuver node on the vessel’s flight path.

soi_change#

An alarm for the next sphere of influence change on the vessel’s flight path.

transfer_window#

An alarm for the next planetary transfer window from the vessel’s current orbit to a target body.

unknown#

The alarm is of a type not recognized by kRPC. Typically this is a type introduced by a mod.

class SpaceCenter.AlarmWarpAction#

The warp action taken when an alarm fires. See SpaceCenter.Alarm.warp_action.

no_change#

Do not change time warp when the alarm fires.

stop_warp#

Drop out of time warp when the alarm fires.

pause_game#

Pause the game when the alarm fires.

class SpaceCenter.AlarmMessageAction#

The on-screen message action taken when an alarm fires. See SpaceCenter.Alarm.message_action.

no_message#

Do not display a message when the alarm fires.

message#

Display a message when the alarm fires.

message_if_not_active_vessel#

Display a message only if the alarm’s vessel is not the currently active vessel.