Alarms#

class SpaceCenter.AlarmManager()#

Alarm manager. Obtained by calling SpaceCenter.getAlarmManager().

AlarmManager.getAlarms()#

A list of all alarms.

Property:

Read-only, cannot be set

Return type:

Array of SpaceCenter.Alarm

AlarmManager.alarmsWithType(type)#

A list of all alarms of the given type.

Arguments:
Return type:

Array of SpaceCenter.Alarm

AlarmManager.alarmWithName(name)#

Returns the first alarm with the given title, or null if no such alarm exists. Alarm titles are not guaranteed to be unique; if more than one alarm shares the given title, the first one found is returned.

Arguments:
  • name (string) – The title of the alarm to return.

Return type:

SpaceCenter.Alarm or null

AlarmManager.addAlarm(time[, title[, description]])#

Create an alarm.

Arguments:
  • time (number) – Number of seconds from now that the alarm should trigger.

  • title (string) – Title for the alarm. Defaults to "Alarm".

  • description (string) – Description for the alarm. Defaults to "".

Return type:

SpaceCenter.Alarm

AlarmManager.addVesselAlarm(time, vessel[, title[, description]])#

Create an alarm linked to a vessel.

Arguments:
  • time (number) – Number of seconds from now that the alarm should trigger.

  • vessel (SpaceCenter.Vessel) – Vessel to link the alarm to.

  • title (string) – Title for the alarm. Defaults to "Vessel Alarm".

  • description (string) – Description for the alarm. Defaults to "".

Return type:

SpaceCenter.Alarm

AlarmManager.addApoapsisAlarm(vessel[, offset[, title[, description]]])#

Create an alarm for the given vessel’s next apoapsis.

Arguments:
  • vessel (SpaceCenter.Vessel) – The vessel.

  • offset (number) – Time in seconds to offset the alarm by. Defaults to 60.0.

  • title (string) – Title for the alarm. Defaults to "Apoapsis Alarm".

  • description (string) – Description for the alarm. Defaults to "".

Return type:

SpaceCenter.Alarm

AlarmManager.addPeriapsisAlarm(vessel[, offset[, title[, description]]])#

Create an alarm for the given vessel’s next periapsis.

Arguments:
  • vessel (SpaceCenter.Vessel) – The vessel.

  • offset (number) – Time in seconds to offset the alarm by. Defaults to 60.0.

  • title (string) – Title for the alarm. Defaults to "Periapsis Alarm".

  • description (string) – Description for the alarm. Defaults to "".

Return type:

SpaceCenter.Alarm

AlarmManager.addManeuverNodeAlarm(vessel, node[, offset[, addBurnTime[, title[, description]]]])#

Create an alarm for the given vessel and maneuver node.

Arguments:
  • vessel (SpaceCenter.Vessel) – The vessel.

  • node (SpaceCenter.Node) – The maneuver node.

  • offset (number) – Time in seconds to offset the alarm by. Defaults to 60.0.

  • addBurnTime (boolean) – Whether the node’s burn time should be included in the alarm. Defaults to true.

  • title (string) – Title for the alarm. Defaults to "Maneuver Node Alarm".

  • description (string) – Description for the alarm. Defaults to "".

Return type:

SpaceCenter.Alarm

AlarmManager.addSOIAlarm(vessel[, offset[, title[, description]]])#

Create an alarm for the given vessel’s next sphere of influence change.

Arguments:
  • vessel (SpaceCenter.Vessel) – The vessel.

  • offset (number) – Time in seconds to offset the alarm by. Defaults to 60.0.

  • title (string) – Title for the alarm. Defaults to "SOI Change Alarm".

  • description (string) – Description for the alarm. Defaults to "".

Return type:

SpaceCenter.Alarm

AlarmManager.addTransferWindowAlarm(vessel, target[, title[, description]])#

Create an alarm for the next planetary transfer window from the vessel’s current parent body to the target body.

Arguments:
  • vessel (SpaceCenter.Vessel) – The vessel.

  • target (SpaceCenter.CelestialBody) – The target body.

  • title (string) – Title for the alarm. Defaults to "Transfer Window Alarm".

  • description (string) – Description for the alarm. Defaults to "".

Return type:

SpaceCenter.Alarm

Note

This relies on KSP’s stock transfer-window alarm logic. If KSP cannot compute a transfer from the vessel’s current parent body to the target, the resulting alarm may not fire at a useful time; in that case the properties on the returned alarm can still be used to inspect or adjust it.

class SpaceCenter.Alarm()#

An alarm. Can be accessed using SpaceCenter.getAlarmManager().

Alarm.getID()#

Unique identifier of the alarm. KSP destroys and recreates an alarm when it is edited. This id will remain constant between the old and new alarms.

Property:

Read-only, cannot be set

Return type:

number

Alarm.getType()#

Type of alarm.

Property:

Read-only, cannot be set

Return type:

SpaceCenter.AlarmType

Alarm.getTitle()#
Alarm.setTitle(value)#

Title of the alarm.

Property:

Can be read or written

Return type:

string

Alarm.getDescription()#
Alarm.setDescription(value)#

Description of the alarm.

Property:

Can be read or written

Return type:

string

Alarm.getTime()#
Alarm.setTime(value)#

Time the alarm will trigger, in seconds since epoch.

Property:

Can be read or written

Return type:

number

Alarm.getTimeUntil()#

Time until the alarm triggers, in seconds.

Property:

Read-only, cannot be set

Return type:

number

Alarm.getEventOffset()#
Alarm.setEventOffset(value)#

Seconds between the alarm going off and the event it references.

Property:

Can be read or written

Return type:

number

Note

For a maneuver alarm that includes the burn time, setting this sets the margin before the start of the burn, and the value read back includes half the burn time.

Alarm.getVessel()#

Vessel the alarm references. null if it does not reference a vessel.

Property:

Read-only, cannot be set

Return type:

SpaceCenter.Vessel or null

Alarm.getNode()#
Alarm.setNode(value)#

Maneuver node the alarm references. Only valid for alarms of type SpaceCenter.AlarmType.maneuver.

Property:

Can be read or written

Return type:

SpaceCenter.Node

Note

Throws an exception if the alarm is not of type SpaceCenter.AlarmType.maneuver.

Alarm.getOriginBody()#
Alarm.setOriginBody(value)#

Origin body for the transfer window. Only valid for alarms of type SpaceCenter.AlarmType.transferWindow.

Property:

Can be read or written

Return type:

SpaceCenter.CelestialBody

Note

Throws an exception if the alarm is not of type SpaceCenter.AlarmType.transferWindow.

Alarm.getDestinationBody()#
Alarm.setDestinationBody(value)#

Destination body for the transfer window. Only valid for alarms of type SpaceCenter.AlarmType.transferWindow.

Property:

Can be read or written

Return type:

SpaceCenter.CelestialBody

Note

Throws an exception if the alarm is not of type SpaceCenter.AlarmType.transferWindow.

Alarm.getWarpAction()#
Alarm.setWarpAction(value)#

The action taken on time warp when the alarm fires.

Property:

Can be read or written

Return type:

SpaceCenter.AlarmWarpAction

Alarm.getMessageAction()#
Alarm.setMessageAction(value)#

The on-screen message behavior when the alarm fires.

Property:

Can be read or written

Return type:

SpaceCenter.AlarmMessageAction

Alarm.getPlaySound()#
Alarm.setPlaySound(value)#

Whether the alarm plays a sound when it fires.

Property:

Can be read or written

Return type:

boolean

Alarm.getDeleteOnDismiss()#
Alarm.setDeleteOnDismiss(value)#

Whether the alarm is deleted automatically once the player has dismissed the triggered message.

Property:

Can be read or written

Return type:

boolean

Alarm.getTriggered()#

Whether the time of the alarm has passed and its actions have been triggered.

Property:

Read-only, cannot be set

Return type:

boolean

Alarm.getActioned()#

Whether the alarm’s actions were triggered and then completed or closed.

Property:

Read-only, cannot be set

Return type:

boolean

Alarm.remove()#

Removes the alarm.

Note

Any further use of this object throws an exception.

class SpaceCenter.AlarmType()#

The type of an alarm. See SpaceCenter.Alarm.getType().

AlarmType.raw#

An alarm for a specific date/time or a specific period in the future.

AlarmType.apoapsis#

An alarm for the next apoapsis of a vessel.

AlarmType.periapsis#

An alarm for the next periapsis of a vessel.

AlarmType.maneuver#

An alarm based on a maneuver node on the vessel’s flight path.

AlarmType.soiChange#

An alarm for the next sphere of influence change on the vessel’s flight path.

AlarmType.transferWindow#

An alarm for the next planetary transfer window from the vessel’s current orbit to a target body.

AlarmType.unknown#

The alarm is of a type not recognized by kRPC. Typically this is a type introduced by a mod.

class SpaceCenter.AlarmWarpAction()#

The warp action taken when an alarm fires. See SpaceCenter.Alarm.getWarpAction().

AlarmWarpAction.noChange#

Do not change time warp when the alarm fires.

AlarmWarpAction.stopWarp#

Drop out of time warp when the alarm fires.

AlarmWarpAction.pauseGame#

Pause the game when the alarm fires.

class SpaceCenter.AlarmMessageAction()#

The on-screen message action taken when an alarm fires. See SpaceCenter.Alarm.getMessageAction().

AlarmMessageAction.noMessage#

Do not display a message when the alarm fires.

AlarmMessageAction.message#

Display a message when the alarm fires.

AlarmMessageAction.messageIfNotActiveVessel#

Display a message only if the alarm’s vessel is not the currently active vessel.